CAE Blue Phantom Combination IUP Ectopic Pregnancy Transvaginal Ultrasound Training Model

(0) No Reviews yet
SKU: MS153925
$10,425.00

Vendor Direct: Longer Lead Times May Apply

CAE Blue Phantom Combination IUP Ectopic Pregnancy Transvaginal Ultrasound Training Model

Blue Phantom’s combination Intrauterine Pregnancy (IUP) and Ectopic Pregnancy Transvaginal ultrasound training model offers the excellent imaging characteristics found in our Intrauterine Pregnancy Transvaginal model as well as Ectopic Pregnancy Transvaginal model
 

Manufactured using Blue Phantom’s patented simulated human tissue, this extremely realistic combination transvaginal medical training model offers the opportunity for clinicians to develop and practice the psychomotor and imaging skills necessary to perform first trimester transvaginal ultrasound exams.
 

With your ultrasound system and Blue Phantom’s IUP and Ectopic Pregnancy Transvaginal phantom, it is possible for users of all levels to learn to scan, identify normal internal pelvic structures and pathology in the gravid first trimester patient using ultrasound sonography.
 

Contains both an intrauterine pregnancy as well as an ectopic pregnancy

  • Both intrauterine and ectopic pregnancies are of a 7 week gestational age fetus complete with amnion and placenta
  • Detailed anatomical features are positioned within a realistic female lower torso
  • Accurately simulates the feel and imaging characteristics of an actual endovaginal ultrasound exam
  • Combination endovaginal model is anatomically correct both externally and internally
  • Allows users to practice all of the elements necessary to gain proficiency in performing transvaginal ultrasound sonography
  • Simulates patient in her first trimester of pregnancy with either ectopic or intrauterine pregnancy
  • Provides the feel and imaging characteristics of an actual endovaginal exam
  • Excellent for 3-D and 4-D ultrasound imaging and reconstruction

 

Develop and practice the psychomotor and imaging skills necessary to perform first trimester transvaginal ultrasound exams

  • Practice using ultrasound system controls
  • Transducer positioning and movement
  • Utilize obstetrical ultrasound calculation packages to measure cysts, crown-rump length (CRL), and the gestational sac

 

Blue Phantom tissue technology accurately simulates the ultrasound imaging characteristics found in the obstetrical and gynecological human patient.

  • Use your own ultrasound system and controls
  • Performs well using any ultrasound system configured with the appropriate transducer
  • Recommended ultrasound transducer: endovaginal ultrasound probe 5.0-12 MHz
  • Excellent for using 2-D, 3-D, and 4-D ultrasound imaging techniques
  • Experience the same quality you expect from imaging patients in a clinical environment

 

This medical training model is excellent for specialties including OB/GYN, emergency medicine, fertility training programs, simulation centers, medical education facilities, and ultrasound manufacturers for ultrasound education on demonstration.
 

All CAE Blue Phantom Models:

  • Feel like real human tissue
  • Synthetic material matches the acoustic characteristics of real human tissue
  • Made of patented latex-free, ultra-durable tissue
  • Provide realistic ultrasound imaging characteristics
  • Will not dehydrate or decompose over time
  • Patented technology
  • Made in the USA

 

Includes:

  • Foam block for stability
  • Privacy skirt
  • User Guide CD
  • Padded soft storage/travel case
  • One (1) year warranty

 

MFG# BPOB1227

  • Intrauterine and Ectopic Pregnancy Transvaginal Ultrasound Training Model from CAE replicates the acoustic properties of human tissue so users can practice imaging skills for diagnosis
  • Endovaginal model is anatomically correct both externally and internally
  • Both pregnancies are of a 7 week fetus complete with amnion and placenta
  • Includes 1 year manufacturer warranty

Product Highlights

  • Intrauterine and Ectopic Pregnancy Transvaginal Ultrasound Training Model from CAE replicates the acoustic properties of human tissue so users can practice imaging skills for diagnosis
  • Endovaginal model is anatomically correct both externally and internally
  • Both pregnancies are of a 7 week fetus complete with amnion and placenta
  • Includes 1 year manufacturer warranty

Transvaginal Ultrasound Training Model


Ratings & Reviews

No reviews available

Be the first to Write a Review