CAE Blue Phantom Lumbar Puncture and Spinal Epidural Ultrasound Models

(0) No Reviews yet
SKU: DM3056179
$4,850.00 to $7,330.00

Vendor Direct: Longer Lead Times May Apply

CAE Blue Phantom Lumbar Puncture and Spinal Epidural Ultrasound Models

The CAE Blue Phantom Lumbar Puncture and Spinal Epidural training models allow practice of lumbar puncture, lumbar epidural, thoracic epidural, and cervical epidural diagnostic and therapeutic procedures
 

This Lumbar Puncture trainer with Lumbar Epidural is available in a variety of configurations to meet your training needs.
 

The Lumbar Puncture model with Spinal Epidural access is excellent in its realism, quality and durability offering you the ability to use ultrasound or utilize blind insertion techniques while performing lumbar puncture or epidural procedures to access the epidural or subarachnoid space.
 

Blue Phantom’s Lumbar Puncture model is superb for needle access as well as the placement of catheters.

  • Practice ultrasound or blind insertion techniques for lumbar puncture or epidural procedures
  • Thread catheters, inject local anesthesia, infuse medications, and obtain manometer measurements

Blue Phantom’s adult spinal epidural and lumbar puncture trainer can be positioned in the upright or lateral decubitus position allowing users to accurately position the model for appropriate training scenarios.
 

Lumbar Puncture

For lumbar puncture and lumbar epidural procedures the use of external landmarks as the iliac crests can be palpated in the model to initially orient the user to the proper access points.
 

Further palpation of the spinous processes provides additional landmarks.
 

Ultrasound can be used for identification of the optimal insertion points, angle of needle insertion, and determination of the depth to the ligamentum flavum, epidural space, and spinal cistern.
 

Blue Phantom’s Lumbar Puncture trainer with Spinal Epidural access is superb in its realism and can be utilized for full procedural training.

  • Allows access to epidural and/or subarachnoid spaces
  • Superb for needle access as well as the placement of catheters
  • May be used in upright or lateral decubitus position
  • Fluid pressures may be increased to simulate pathological scenarios
  • Compatible with any ultrasound imaging system configured with the appropriate ultrasound transducer
  • Ultrasound may be used to:
    • Identify optimal insertion points
    • Visualize angle of needle insertion
    • Determine depth to ligamentum flavum, epidural space, and spinal cistern
  • Realistic tissue response:
    • Characteristic “pop” when traversing the ligamentum flavum
    • Loss of resistance when entering the epidural space
    • Cerebral spinal fluid flow when the spinal cistern is accessed

Spinal Injection

  • Self-healing tissue allows local anesthetics and epidural fluid infusions to be injected
  • Fluids are automatically expelled so that the model can be used repeatedly for training
  • Cerebral fluid flow provides immediate feedback about needle placement and procedural complications
  • Simulated cerebrospinal fluid is easily replaced using quick refill ports

CAE Blue Phantom Models

Blue Phantom models are extremely durable and self-healing which saves you money by reducing the need to repeatedly purchase replacement parts.
 

Blue Phantom synthetic tissue matches the acoustic characteristics of real human tissue so when you use your ultrasound system on our training models, you experience the same quality you expect from imaging patients in a clinical environment.
 

Blue Phantom spinal epidural and lumbar puncture training model will perform well using any ultrasound imaging system configured with the appropriate ultrasound transducer.

  • Feel like real human tissue
  • Synthetic material matches the acoustic characteristics of real human tissue
  • Made of patented latex-free, ultra-durable tissue
  • Realistic ultrasound imaging characteristics
  • Contain hyperechoic, hypoechoic, and echolucent masses
  • Will not dehydrate or decompose over time
  • Patented technology

Includes

  • 235 mL bottle of simulated clear cerebrospinal fluid
  • One (1) year warranty
  • Lumbar Puncture and Spinal Epidural Ultrasound Models from CAE replicate the acoustic properties of human tissue so users can practice imaging skills for diagnosis and anesthesia, Thread catheters, inject local anesthesia, infuse medications, and measure manometryCharacteristic pop is felt when the needle traverses the ligamentum flavum
  • Includes 1 year manufacturer warranty

Product Highlights

  • Lumbar Puncture and Spinal Epidural Ultrasound Models from CAE replicate the acoustic properties of human tissue so users can practice imaging skills for diagnosis and anesthesia, Thread catheters, inject local anesthesia, infuse medications, and measure manometryCharacteristic pop is felt when the needle traverses the ligamentum flavum
  • Includes 1 year manufacturer warranty

Ratings & Reviews

No reviews available

Be the first to Write a Review